Methacrylate-based resin for rebar fixing
BATIMIX A-200 is a methacrylate styrene-free resin used for various repair and construction applications.
BATIMIX A-200 is a versatile product, suitable for a wide variety of construction applications and civil engineering fields of use. It is particularly recommended for the following applications:
BATIMIX A-200 exhibits the following characteristics:
BATIMIX A-200 is not a hazardous material. However, it should not be swallowed or allowed to come into contact with skin and eyes. Suitable gloves and goggles should be worn. For additional information, kindly refer to the product’s Material Safety Data Sheet.
Fixing reinforcement with BATIMIX A-200 complies with BAEL 91 specifications.
The BAEL (Reinforced Concrete at Limit States) specifications are a set of design and calculation rules used for reinforced concrete structures. The BAEL 91 specifications are a particular version of the BAEL specifications published in 1991.
BAEL 91 specifications are used by designers of reinforced concrete structures in France and are widely used in the construction industry in France. The specifications include the rules for the design of the reinforcements, the calculation of the loads and constraints, the resistance of the materials.
The general steps to be implemented when using BATIMIX A-200 can be summarized as follows:
1-Drill the location to be repaired, and clean well 2-Inject BATIMIX A-200 to the required depth 3-Insert the bar 4-Allow enough time to achieve full curing (refer to the table below)
\ Ambient temperature, ºC
-5 to 5 5 to 10 10 to 20 20 to 40 Working time 15 min 10 min 4 min 1.5 min Curing time for dry concrete 5 hrs 100 min 75 min 45 min Curing time for wet concrete 7.5 hrs 160 min 110 min 70 min
For proper products’ usage, Holderchem provides complete technical laboratory support and on-site assistance pertaining to the application methods.
Diameter Minimum resistance Elasticity Maximum load
mm at breaking point,daN daN daN
8 2766 2515 2187 10 4317 3925 3413 12 6215 5650 4913 14 8470 7700 6695 16 11055 10050 8739 20 17270 15700 13652
\ Concrete of 20-25 MPa Concrete of 35-45 MPa
Bar D Depth L F Depth L F diameter drill bit min/max, min/max, min/max, min/max, mm diameter mm daN mm daN
8 10 80 / 330 530 /2187 80/219 800/2187 10 12 100 / 429 795 /3413 100/28 1200/3413 14 18 140 / 561 1669 /6695 140/372 2520/6695 16 20 160 / 660 2119 /8739 160/437 3200/8739 20 25 200 / 824 3311 /13652 200/546 5000/13652 Data for steel HA Fe E500.
The working load is determined from the equation: L = β × (F / D), where L is the depth (mm), F is the maximum load possible on the bar (daN), D is the drill bit diameter, and β is a parameter linked to the quality of concrete. The β is taken equal to 1 or 1.51 for concrete having 20 to 25 MPa or 35 to 45 MPa, respectively.
Temperature, ºC -20 0 20 40 60 80 100 120 140
Reduction factor 1 1 1 1 0.9 0.7 0.5 0.4 0.3
BATIMIX A-200 has a minimum shelf life of 12 months if kept unopened and stored at temperatures ranging from 5 to 25 ºC.